Fire detection and alarm systems

Fire detection and alarm systems

About the system

Designed for the building use, detection needs and evacuation scenario.

System provider
Özkartay

System scope

  1. Conventional or addressable system selection based on the building and operating conditions
  2. Layout of detectors, manual call points, audible and visual alarms and the control panel
  3. Coordinated design of zones or loops, cable routes and required system integrations
  4. Installation, testing and commissioning scope defined with the project

Frequently asked questions

How is the choice between conventional and addressable systems made?

Conventional arrangements indicate alarms by zone; addressable arrangements can indicate the device address supported by the system. Select against building size, compartment layout, alarm/fault location needs and integration requirements.

Can the same detector be used in every space?

Select smoke, heat or other detection methods against the expected fire, ceiling and air movement, and operating conditions such as dust or steam. Check detector model, placement and panel compatibility against project data.

How does detection coordinate other fire-safety systems?

Define audible/visual warning, evacuation, suppression control and any ventilation, door or other interlocks in a written cause-and-effect scenario. Check each output function and fault behaviour during commissioning tests.

Design and installation guide

Early warning and emergency scenario management: fire detection and alarm systems

Time is critical in fire response. Early detection of smoke, rising temperature or flame helps warn occupants, initiate evacuation and activate the protection measures defined for the project.

Özkartay fire detection and alarm solutions are designed by assessing building use, compartments and zones, potential fire scenarios, occupancy, evacuation arrangements and the existing electrical infrastructure together. System architecture, detection technology and building-system interfaces are selected around these needs.

01

How are fire detection and alarm systems designed?

Design considers fire detection, location reporting, occupant warning and the required control functions as one coordinated system.

  1. System architecture: addressable or conventional

    Conventional systems report an alarm at zone level. Addressable systems display the address of the device in alarm and its programmed location. This distinction concerns alarm localisation; detection sensitivity also depends on detector technology, settings and site conditions.

  2. Field-device layout

    Detectors, manual call points, sounders, beacons and the control panel are positioned with regard to room dimensions, ceiling geometry, airflow, environmental conditions and escape routes. Audible and visual warning coverage is assessed as part of the design.

  3. Verification of detection, warning and control together

    Zones and loops, cabling, panel capacity, manual alarm initiation, audible and visual warning and the required interfaces are defined by the project. Alarm, fault and control scenarios are tested, with device locations and system behaviour verified through commissioning records.

02

Building-system integration: cause-and-effect sequence

A fire detection system can participate in building emergency functions through compatible interfaces as well as issue warnings. The approved cause-and-effect matrix defines which alarm initiates each action, and the sequence is tested on site.

HVAC and smoke control

Normal ventilation
The fire strategy determines the response of the relevant air-handling units and dampers to help limit smoke spread.
Smoke extraction and pressurisation
Smoke extraction and stair pressurisation are treated as control functions separate from normal ventilation, with operation and feedback verified against the fire strategy.

Access control and escape doors

Safe egress
Emergency operation is defined for access-control locks and turnstiles that could obstruct egress, with the relevant locks released to allow occupants to leave safely.
Maintaining fire compartments
Releasing an escape lock and holding a fire door open are different actions. Release of fire-door hold-open devices and door closure are coordinated with the compartmentation strategy.

Lift recall

Recall to the designated safe landing
Fire-mode lift recall is designed together with the lift control system and approved sequence. The recall landing is not automatically assumed to be the ground floor in every building.
Interface and sequence testing
Control interfaces are tested with the relevant teams, taking account of the alarm location, any alternative recall landing and the operating strategy for special-purpose lifts.

Suppression-system interfaces

Gaseous and pre-action systems
Alarm and confirmation signals for gaseous or pre-action suppression are defined in coordination with the selected suppression control arrangement.
Approved release sequence
Automatic discharge is managed through suitable releasing controls and approved confirmation conditions. Delays, manual functions, warnings and system feedback are verified during project acceptance tests.

03

Detection solutions by facility type

Detector selection depends on the expected fire signature, ceiling and airflow as well as the normal operating conditions of the facility.

Industrial facilities

Site conditions
Dust, humidity, steam, process temperatures and different combustible materials can affect detection performance and unwanted-alarm risk.
Design approach
Smoke, heat, multi-sensor or flame detection is assessed against the fire hazard and environment. Suitable Ex protection is checked separately where an explosive atmosphere is present. Appropriate devices and positioning help reduce unwanted alarms.

High-ceiling warehouses and atriums

Site conditions
High ceilings, large open spaces, airflow and maintenance access affect spot-detector positioning and the movement of smoke to the sensing location.
Design approach
Aspirating smoke detection (ASD) or beam detectors are considered where appropriate for the project. Sampling pipes, the beam line of sight, rack layout and airflow are planned together. VESDA is a trade name used in aspirating smoke detection.

Hotels, hospitals and residential buildings

Site conditions
Numerous rooms, different occupant needs and floor-specific evacuation requirements make prompt alarm localisation and clear warnings particularly valuable.
Design approach
Addressable systems provide detailed device and location reporting. Voice evacuation and zoned warnings are assessed together with the evacuation plan where required. System requirements are established for the building use, scale and applicable project rules.

04

Detection system comparison

Scroll the table horizontally to view every column.

Detection system comparison
System / technologyExample applicationDetection and localisation approachReporting method
Addressable systemHotels, hospitals, shopping centres and multi-compartment buildingsDetailed alarm localisation by device address; detection depends on the selected detectorDevice address and programmed location
Conventional systemSuitable smaller premises and facilities with a limited zone structureZone-level alarm localisation; detection depends on the selected detectorZone identification
Aspirating smoke detection (ASD)Data centres, suitable high-bay warehouses, museums and sensitive areasAir sampling through pipes; early warning depends on the product and designDetector, pipe/sector or sampling-point identification, depending on the product

Addressable and conventional describe system architecture; ASD is a detection technology that can interface with these architectures where compatible. This table is a general selection guide. Sensitivity, location resolution, warning coverage and interfaces are verified against the selected devices and engineering design.

Effective fire detection and alarm combines early detection, clear warnings and a correctly designed emergency sequence. Özkartay plans the process around facility needs, from device selection and building-system integration to site testing and commissioning.