Pre-action sprinkler system

Pre-action sprinkler system

About the system

A sprinkler system controlling water admission through detection and the selected single- or double-interlock arrangement.

System provider
Özkartay

System scope

  1. The detection system and sprinkler head are assessed together
  2. The valve opens when the selected interlock conditions are met; water discharges through open sprinklers
  3. Detection, panel, valve and sprinkler sequences are tested together
  4. Reduces the risk of accidental water discharge
  5. Used in data centres, museums, archives and sensitive areas

Frequently asked questions

What makes pre-action different?

In a single-interlock system, fire detection opens the valve and admits water to the pipes; a closed sprinkler does not discharge water. In a double-interlock system, detection and pressure loss associated with sprinkler operation are both required to open the valve. Define release conditions from the selected system diagram.

Where is it preferred?

It is preferred in data centres, museums, archives and sensitive areas where water damage is critical.

What components are included?

Sprinkler heads, detection and control panel, pre-action valve set, pipework and monitoring devices are defined by the project.

Design and installation guide

Pre-action sprinkler system: selection and application guide

A preaction system coordinates detection with admission of water to the sprinkler piping through the selected interlock arrangement. Single- and double-interlock options have different release conditions; select the arrangement for the protected space and operating scenario.

A pre-action sprinkler system controls water admission to the pipe network through the selected interlock arrangement. In a single-interlock system, fire detection opens the valve; a double-interlock system requires both detection and the pressure loss associated with sprinkler operation. Water discharges through open sprinklers. Select the arrangement for the risk and operating scenario of the data centre, museum, archive or sensitive-equipment space.

01

Operating arrangement and engineering

Selection considers the product function, the protected risk and operating conditions together. These steps support the site survey and quotation.

  1. Interlock and detection scenario

    Define detection signals, pipe-pressure supervision and valve-opening conditions from the selected system diagram. Do not assume one activation sequence for every preaction system.

  2. Supervision and operational coordination

    Supervise the panel, valve, air supply and impairment states. Plan loss of protection during maintenance and restoration with the operating team.

  3. Hydraulic calculations and layout

    Calculate hazard classification, storage or process data, pipe sizes and water demand at the critical point together. Pump, tank and head/nozzle selection are elements of this design.

  4. Testing and maintenance

    Verify water supply, valve/alarm functions and the relevant system scenario during commissioning. Record system-specific testing and maintenance tasks in operating records.

02

Applications and site planning

These examples show why placement and equipment requirements can differ between facilities using the same product.

Sensitive equipment spaces

Site requirement
Operational consequences of unintended water discharge.
Application approach
Assess fire risk, detection design and water-delivery needs together.

Spaces requiring coordinated operation

Site requirement
Alarm confirmation and maintenance supervision needs.
Application approach
Connect interlock conditions to a written cause-and-effect scenario and function testing.

03

Pre-quotation checklist

Scroll the table horizontally to view every column.

Pre-quotation checklist
Check itemProduct / applicationInformation to assess
System arrangementWater admission through the selected interlockDesign diagram and operating scenario
Water supplyPump, tank and pipe networkHydraulic demand and available supply
SpaceFire hazard and environmental conditionsStorage, temperature and obstructions
Handover and maintenanceFunction tests and recordsSystem-specific inspection plan

Select the sprinkler arrangement through a combined assessment of hazard, environment and water supply. Survey and engineering calculations establish its layout, equipment and operating scope.