Skip to content

Fire hose cabinets

Fixed cabinet solutions that house hose, valve and access equipment together.
Explore the reel hub and connection details
Explore the design and installation guide

CONNECTION DETAILS

A closer look at the reel hub.

Explore the brass waterway, flanged hub and hose-tail fitting through individual detail views of the assembly.

Overall view of the brass U-shaped waterway, silver-colored flanged reel hub and brass hose-tail fitting.
Reel hub with a central water passageProduct visualization

Water transfer continues as the reel turns.

At a minimum pressure of 4 bar, the hub allows a water flow of 100 litres per minute. The rotating hub with a central water passage is designed to maintain water transfer to the hose as the reel turns. The U-shaped waterway, flange and hose-tail fitting come together around this hub.

Water flow rate
100 L/minAt a minimum pressure of 4 bar
Close view of the reel hub’s silver-colored flange with four mounting holes and the brass hexagonal nut at the U-tube connection.

Flange and hub connection

The flange is made entirely from aluminium and its four mounting holes form the reel hub’s mounting and connection surface. The central hexagonal nut sits at the connection between the U-shaped tube and the hub.

Close view of the open connection end and curved waterway of the brass U-shaped tube attached to the hub.

Brass U-shaped waterway

The curved brass tube forms the waterway between the water line and the reel’s central connection. This view shows its U-shaped form and open connection end together.

Close view of the ribbed end, hexagonal connection section and hub-connected elbow of the brass hose-tail fitting.

Hose-tail connection

The ribbed brass hose tail provides the hose connection point. The hexagonal section and threaded connection sit where the fitting joins the body.

Design and installation guide

Fire hose cabinets: positioning, hose selection and first-response readiness

A fire hose cabinet provides an accessible interface between the water system and the user. Its position, door opening, actual hose route and water performance at the discharge point matter as much as its contents.

The Özkartay catalog includes glass- and steel-front cabinets, versions with an extinguisher compartment, foam-system and hydrant-type cabinets, and hose trolleys. Selection follows facility use and available water connections.

01

Cabinet selection and site positioning

Coordinate space, access and water demand to create a usable response point.

  1. Risk and use scenario

    Assess solid-material or flammable-liquid hazards, responder competence and the emergency plan. A foam cabinet requirement depends on the fuel involved.

  2. Access and hose route

    Keep access clear and check door and reel movement. Assess hose length against its actual route through doors and corridors, rather than a straight-line distance alone.

  3. Hydraulic suitability

    Calculate the combined flow and pressure demand of the valve, hose and nozzle. Connection size or hose length alone does not establish adequate water performance.

  4. Installation and connections

    Plan recessed or surface mounting around wall construction, fixings and pipe entry. Cabinet opening is coordinated with the escape route.

  5. Checks and maintenance

    Record checks of the hose, reel, valve, nozzle, door and any extinguisher compartment. Track damage, leaks and missing equipment through the maintenance programme.

02

Cabinet and hose options

Match documentation and technical characteristics to the selected model; cabinet arrangements do not all work in the same way.

Glass- or steel-front cabinet

Positioning
Choose surface or recessed installation around the space and architectural conditions.
Hose arrangement
For 1" cabinets, consider the 20, 25 or 30 m hose options recorded for the model.

Cabinet with extinguisher compartment

Scope
Coordinate the hose system and the space allocated to a portable extinguisher.
Selection
Select extinguisher type and capacity for the local hazard; a compartment does not make every extinguisher suitable.

Foam-system cabinet

Agent compatibility
Select AFFF, AFFF-AR, synthetic or fluorine-free (NFF / F3) concentrate for the protected liquid. Match proportioning to the selected concentrate documentation and proportioning equipment; one ratio does not apply to every foam family.
Water and connections
Review the hose, branchpipe, inductor and 1" / 2" connection options as one flow arrangement.

Hydrant cabinet and hose trolley

Site use
Check connection compatibility, outdoor exposure and the route for moving equipment.
Hose standard
EN 671-1 covers semi-rigid hose reels; EN 671-2 covers lay-flat hose systems. Confirm the cabinet’s documentation against its actual hose arrangement.

03

Cabinet planning by application

Equipment availability is supported by access and personnel readiness.

Factories and workshops

Need
Accessible response points around machines and production lines.
Planning
Coordinate cabinet positions with production flow and review equipment and hose routes when operations change.

Storage and logistics

Need
Access affected by racks, storage and vehicle movements.
Planning
Plan clear cabinet approaches and aisles; assess hose reach against the rack layout.

Commercial and public buildings

Need
Coordination with escape routes and user familiarity.
Planning
Check door opening and visibility, and connect training and maintenance records to the facility plan.

Flammable liquids and outdoor areas

Need
Fuel compatibility, weather exposure and hydrant connections.
Planning
Select foam or hydrant arrangements around the concentrate, water performance, connections and authorised responders.

04

Cabinet selection checklist

Scroll the table horizontally to view every column.

Cabinet selection checklist
ArrangementPriority checkQuotation input
Glass / steel frontAccess and hose routeMounting arrangement and hose length
Extinguisher compartmentExtinguisher suitabilityCompartment and extinguisher dimensions
Foam systemConcentrate / inductor compatibilityFuel, water data and mixing proportion
Hydrant / hose trolleyConnections and movement accessSite layout and equipment scope

Use dimensions and documentation from the selected product record. Response is undertaken by trained personnel within the facility’s emergency plan.

A usable fire cabinet brings suitable equipment, adequate water performance, clear access and trained personnel together. Plan selection, installation and maintenance as one arrangement.

Tell us about your project. We’ll help find a solution that fits.

Send a request